{"product_id":"titahap-prosthesis-type-vario-total-torp","title":"TitaHAp-prosthesis type Vario Total (TORP)","description":"\u003cul\u003e\n\u003cli class=\"ql-align-justify\"\u003e\n\u003cstrong\u003eHead:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe head plate or disk is the part that is placed against the tympanic membrane. It is designed to provide stability and support for the device.\u003c\/li\u003e\n\u003cli class=\"ql-align-justify\"\u003eThese devices can be made using fluoroplastic material. Fluoroplastic is a non-reactive and low-friction material that can be used for coating or lining certain parts of the device.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDesign Benefit:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Middle ear implants restores or improves the hearing ability by providing structural support to ossicular chain thereby maintaining stability of middle ear resulting in effective sound transmission which enhances speech perception.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDuration of Use:\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eLong-term use (Normally intended for continuous use for more than 30 days) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntended Purpose:\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003eMiddle ear implants are used to reconstruct, provide structural support to the ossicular chain (i.e., Incus, Malleus \u0026amp; Stapes) facilitating stability in the middle ear resulting in improved hearing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClinical Indications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImmobility of ear bones (Malleus, Incus and Stapes). \u003c\/li\u003e\n\u003cli\u003eOtosclerosis\/congenital stapes fixation and malleus fixation. \u003c\/li\u003e\n\u003cli\u003eTraumatic injury to the ossicles. \u003c\/li\u003e\n\u003cli\u003eChronic otitis media with conductive hearing loss. \u003c\/li\u003e\n\u003cli\u003eMalformation of the middle ear. \u003c\/li\u003e\n\u003cli\u003eRevision surgery due to insufficient hearing improvement as may be caused by prosthesis dislocation. \u003c\/li\u003e\n\u003cli\u003eRevision operation on a mal-positioned prosthesis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMiddle Ear Implants (MEIs) are medical devices designed to restore the function of the middle ear or enhances the conduction of sound in cases where there are pathologic changes affects the conductive hearing mechanism. \u003c\/li\u003e\n\u003cli\u003eMEIs transmits sound effectively from the tympanic membrane to the inner ear. \u003c\/li\u003e\n\u003cli\u003eMEIs should be securely fixed in place to ensure stability and long term functionality. \u003c\/li\u003e\n\u003cli\u003eThe MEIs replaces ear bones(stapes, incus, malleus) which are part of the natural ossicular chain. It's design facilitates secure attachment of the bones and oval window. \u003c\/li\u003e\n\u003cli\u003eMEIs come in various sizes and shapes to accommodate the anatomical variations of the patients. The appropriate sizes and shapes should be selected to ensure a proper fit and optimal sound transmission.\u003c\/li\u003e\n\u003cli\u003eMEI remains stable within the middle ear and is capable of withstanding the mechanical stresses associated with normal middle ear function. \u003c\/li\u003e\n\u003cli\u003eMEI are easy to insert during the surgical procedure. It has a smooth surface and a shape that allows for smooth insertion without causing trauma to the delicate structures of the middle ear.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Information \u0026amp; Contraindications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe device is for single use only. Do not re-sterilize or re-use.\u003c\/li\u003e\n\u003cli\u003eDo not re-sterile- if the device is resterilised, it may cause harm or infection to patient due to re-sterilization of the device.\u003c\/li\u003e\n\u003cli\u003eThe ENT surgeon is encouraged to carefully choose Middle ear Implant size and material to meet the needs of each specific clinical situation, while minimizing adverse effects.\u003c\/li\u003e\n\u003cli\u003eDo not use if the packaging has been opened or damaged.\u003c\/li\u003e\n\u003cli\u003eThe Titanium Middle Ear Implant have been determined to be MR conditional. Material is safe up to 1.5 T in Magnetic field.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContraindications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAcute otitis media, which can cause implant displacement \u003c\/li\u003e\n\u003cli\u003eAcute and chronic infectious diseases \u003c\/li\u003e\n\u003cli\u003eKnown wound healing disorders\u003c\/li\u003e\n\u003cli\u003eDislocated, fractured or fixed stapes footplate and hyper mobile stapes footplate (“Floating Footplate”) \u003c\/li\u003e\n\u003cli\u003eTreatment with cytotoxic drugs or radiotherapy (e.g., for malignant tumour)\u003c\/li\u003e\n\u003cli\u003eParticular material allergy \u003c\/li\u003e\n\u003cli\u003eGeneral impairment of wound healing \u003c\/li\u003e\n\u003cli\u003ePatient suffering from alcohol, drug, or nicotine abuse \u003c\/li\u003e\n\u003cli\u003eMedical issues surrounding the middle ear implant surgery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial:\u003c\/strong\u003e CP Titanium Medical Grade ASTM F 67 \u0026amp; HAP (1 Unit\/Box, Gamma Sterile)\u003c\/p\u003e\n\u003ctable style=\"border-collapse: separate; width: 99.4234%; height: 5px; border-radius: 15px; border: 1px solid rgb(2, 102, 159);\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 65px; background-color: rgb(224, 242, 242);\"\u003e\n\u003cth style=\"width: 16.9715%; height: 65px; text-align: center; border-top-left-radius: 15px; border-bottom: 1px solid rgb(2, 102, 159);\"\u003e\u003cstrong\u003eRef.\u003cbr\u003eNumber\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 20.4654%; text-align: center; border-bottom: 1px solid rgb(2, 102, 159);\"\u003e\u003cstrong\u003eShaft\u003cbr\u003eDiameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 19.0765%; height: 65px; text-align: center; border-bottom: 1px solid rgb(2, 102, 159);\"\u003e\u003cstrong\u003eDisk\u003cbr\u003eDiameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 19.771%; text-align: center; border-bottom: 1px solid rgb(2, 102, 159);\"\u003e\u003cstrong\u003eFunctional Length\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 23.0953%; height: 65px; text-align: center; border-top-right-radius: 15px; border-bottom: 1px solid rgb(2, 102, 159);\"\u003e\u003cstrong\u003eTotal\u003cbr\u003eLength\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 33.0035px;\"\u003e\n\u003ctd style=\"width: 16.9715%; height: 33.0035px; text-align: center;\"\u003eE1208\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 20.4654%; text-align: center;\"\u003e0.30\u003c\/td\u003e\n\u003ctd style=\"width: 19.0765%; height: 33.0035px; text-align: center;\"\u003e3.00\u003c\/td\u003e\n\u003ctd style=\"width: 19.771%; text-align: center;\"\u003e7.00 - 3.00\u003c\/td\u003e\n\u003ctd style=\"width: 23.0953%; height: 33.0035px; text-align: center;\"\u003e7.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003eAll measurements are in mm\u003c\/p\u003e","brand":"EON Meditech AU","offers":[{"title":"Default Title","offer_id":44685300826200,"sku":"E1208","price":10.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0717\/7728\/8280\/files\/70_18.jpg?v=1788145486","url":"https:\/\/eonmeditech.com.au\/products\/titahap-prosthesis-type-vario-total-torp","provider":"EON Meditech AU PTY. LTD.","version":"1.0","type":"link"}