Heat/Moisture Exchanger (HME)

Heat/Moisture Exchanger (HME)

Air HME

Please log in to view this Product Price. If you don't have an account, register and our team will get you set up.

Skip to product information
Heat/Moisture Exchanger (HME)

Laryngology

EA91001

Heat/Moisture Exchanger (HME)

Link copied!

Heat and moisture exchanger (HME) designed to warm and humidify inhaled air, helping reduce mucus production and airway irritation.

Surgeon Verified

Specification

Please log in to view this Product Price. If you don't have an account, register and our team will get you set up.

Request a Quote / Bulk Pricing ➜

CE Marked Products

Worldwide Shipping

Secure Payment

Surgeon Approved

The Heat/Moisture Exchanger (HME)s traps heat and moisture from exhaled air and makes inhaled air more humid and warmer to reduce mucus generation and irritation in wind pipe to make patient comfortable. It is artificial nose for laryngectomy patient.

It comes in different level of humidification, breathing Resistance and filtration that makes to use in different situations.

 1) Air HME – When you are doing daily routine work

 2) Moist HME – When you are at rest.

 3) Slim HME – When you are doing daily routine work.

It is recommended to use HME continuously. When continuously using an HME the pulmonary function is likely to improve in a majority of patients, and respiratory problems, e.g., coughing and mucus production subsequently decrease.

Intended purpose

The HMEs are a single use, specialized device intended for patients breathing through a tracheostoma.

Duration of Use

Short-term use

Performance characteristics

Touch-free HMEs restore essential airway climate by warming and humidifying inspired air, which significantly reduces chronic coughing and mucus production.

 Clinical Indications

Touch-free Heat and Moisture Exchangers (HMEs) are clinically indicated for total laryngectomy patients with a fully healed tracheoesophageal puncture (TEP) who use a voice prosthesis for communication and require dual-handed functional freedom for tasks like driving, working, or typing. They are also prescribed to minimize the risk of germ transmission from manual stoma contact, provided the patient has a flat, stable peristomal surface capable of maintaining an airtight adhesive seal under respiratory pressure

 Contraindications

  • The HMEs are not intended to be used by patients unable to remove or operate the device, unless the patient is under constant supervision of a clinician or a trained caregiver. For example, patients who are unable to move their arms, patients with decreased levels of consciousness, or patients with diseases that put them at risk for unpredictable periodic loss of consciousness.
  • Do not use the HMEs in combination with cuffed tracheal cannula; breathing may be restricted and suffocation may occur.
  • Do not use on patients with a low tidal volume, as the added dead space may cause CO2 (carbon dioxide) retention at too low tidal volume.

Safety

  • Always test the function of the HME Cassette prior to use. The top lid should immediately return to its open position after releasing the finger.
  • Do not disassemble HME Cassette since this will interfere with its proper function
  • Do not reuse the HME Cassette or attempt to rinse it with water or any other substance. This will substantially reduce the function of the HME. Additionally, the risk of potential infections may increase due to bacterial colonization of the foam.
  • Do not use HME Cassette longer than 24 hours. The risk of potential infections may increase with the time of use due to bacterial colonization of the foam.
  • Do not administer medicated nebulizer treatment over the device since the medication can become deposited in the device.
  • Do not use humidifiers or heated humidified oxygen via a mask over the tracheostoma while using the device. The HME will become too wet. If oxygen therapy is required, use only non-heated humidified oxygen.
  • Be careful not to exert pressure on the lid of the HME unintentionally. Unintentional or accidental closing of the top lid may cause difficulty in breathing.
  • Always inform the patient, caretakers and others about the closing feature of the HME cassette to ensure that they understand its function. Closing the airway to allow voicing is a well-known feature for the laryngectomized patient with voice prosthesis. For patients without voice prosthesis or tracheostomized patients this feature might be unknown.

Operating instruction

To Attach Hold device and press gently into the connector of the attachment device. Breathe normally.

To Speak

To speak, press the top lid of the HME down with a finger.

To Remove

Hold Device and pull sideway gently until it disconnects with attachments.

Note: Always release the lid completely at inhalation to avoid increased breathing resistance. To remove HME Cassette, hold the attachment device in place with two fingers and remove the HME Cassette from the holder.

Ref. Number Description Units/Box
Non-Sterile
EA91001 Air HME 30 Units
EA91002 Moist HME 30 Units
EA91006
Slim HME - Air
30 Units
EA91007
Slim HME - Moist
30 Units


Special Instructions

Provide any specific requirements or notes related to your order. Our team will review and accommodate where possible.

EN ISO 13485 Certified

CE Marked Products

Worldwide Export

25+ Years Trusted

Medical Grade Products

You May Also Need

Frequently ordered together

View all products 🡥

Browse by Category

Comprehensive ENT product portfolio engineered for surgical precision.

View all products 🡥

Otology Products
Otology Products

Otology Products

Audiology
Audiology

Audiology

Rhinology Products
Rhinology Products

Rhinology Products

Laryngology Products
Laryngology Products

Laryngology Products

ENT Instruments
ENT Instruments

ENT Instruments

PVA Dressings
PVA Dressings

PVA Dressings

Social Proof

What surgeons say about us

Voices from the operating theatre, ENT specialists across the globe share their experience.

The product quality and consistency are highly reliable. The design reflects a strong understanding of both practitioner needs and patient comfort.

Dr. Emily C

ENT Specialist

The ordering process and product availability have been seamless. We value the consistency in quality and the professionalism in handling bulk requirements.

Michael T

Procurement Manager

The devices integrate well into routine clinical workflows. Ease of use and dependable performance make them a practical choice for daily practice.

Dr. Liam O

Otolaryngologist

From a usability perspective, the products are intuitive and patient-friendly. This significantly improves efficiency during procedures and follow-ups.

Dr. Nathan R

ENT Consultant

The brand demonstrates strong manufacturing standards and reliable supply capabilities, which are essential for maintaining trust in the Australian market.

James W

Healthcare Distributor

The overall build quality and clinical reliability are impressive. The products align well with professional standards and support consistent outcomes in day-to-day practice.

Dr. Olivia B

ENT Surgeon

Support and communication have been excellent. Having a responsive team makes a significant difference in ongoing operations and procurement planning.

Daniel H

Practice Manager

The focus on patient comfort and ease of use is clearly evident. It enhances the overall treatment experience from both clinician and patient perspectives.

Rachel E

Allied Health Professional

Reliable. Compliant. Clinically Designed.

Choose a Trusted ENT Solution

Engineered to meet professional standards and support consistent outcomes in both clinical and home care settings.

EN ISO 13485 Certified

CE Marked Products

Worldwide Shipping

25+ Years Trusted

Medical-Grade Quality

Designed and manufactured under strict clinical standards.

Certified & Compliant

Manufactured in certified facilities aligned with global standards.

Trusted by Professionals

Used by healthcare providers and clinical environments.

Dedicated Support

Guidance and assistance whenever you need it.

Common Questions

Frequently Asked Questions

Have a question not covered here? Our team is ready to help, reach out via email or phone and we'll get back to you within one business day.

Still have questions?

Our clinical and sales teams are happy to assist with product, order, or regulatory queries.

+61 410 737 246

info@eonmeditech.com.au

Who is this product intended for?

This product is designed for use by healthcare professionals and/or individuals, depending on its intended application. Please refer to the product details or consult a medical professional if unsure.

Is this product suitable for home use?

Some products are designed for home use, while others are intended for clinical environments. Check the product specifications to confirm suitability.

Are your products compliant with quality standards?

Yes, all products are manufactured under internationally recognized quality systems and aligned with applicable regulatory requirements.

How do I use this product correctly?

Each product includes usage instructions or guidance materials. For best results, follow the instructions carefully or consult a healthcare professional.

Do you offer bulk or institutional purchasing?

Yes, we support bulk orders for clinics, hospitals, and distributors. Please contact our sales team for more information.

What is the delivery timeline?

Delivery times vary based on location and availability, but we aim to fulfill orders within standard Australian shipping timelines.

What should I do if I need support or face an issue?

If you need assistance, our support team is available to help with product guidance, troubleshooting, or order-related queries.

Stay Updated

Get surgical insights & product updates

Join 2,000+ ENT surgeons and distributors receiving our product newsletters.

info@eonmeditech.com.au

+61 410 737 246

81a Eggleton Street, Blacktown, NSW 2148, AU