Laryngectomy Tube

Laryngectomy Tube

Standard / 8/36

Please log in to view this Product Price. If you don't have an account, register and our team will get you set up.

Skip to product information
Laryngectomy Tube

Laryngology

E3110836S

Laryngectomy Tube

Link copied!

Silicone or TPE laryngectomy tube designed to maintain tracheostoma patency and support airway access after laryngectomy or tracheostomy.

Surgeon Verified

Reference
Specification

Please log in to view this Product Price. If you don't have an account, register and our team will get you set up.

Request a Quote / Bulk Pricing ➜

CE Marked Products

Worldwide Shipping

Secure Payment

Surgeon Approved

A Laryngectomy Tube is a device made up of silicone or thermoplastic elastomer (TPE) material which is designed to stabilize tracheostoma and maintain the airway through stoma after the laryngectomy or tracheostomy. The device is inserted into the stoma of the trachea to facilitate ventilation and keep the stoma open.

  • Laryngectomy tube is available in 2 variants: Standard and fenestrated

Design Benefit

To maintain airway availability and to keep the trachea open.

Design Characteristic

A laryngectomy tube and laryngectomy button eyelets are used to hold the tracheostoma open and maintain an airway through the stoma. Eyelets (wings) prevent the laryngectomy tube and laryngectomy button from slipping into the trachea.

Intended purpose

Laryngectomy Tube and Laryngectomy Button is designed to stabilize tracheostoma and maintain the airway through stoma following laryngectomy or tracheostomy.

Duration of Use

Long-term (up to 6 months)

Performance characteristics

To maintain airway availability and to maintain the opening of stoma.

Clinical Indications

  • Laryngectomy/Tracheostomy
  • Tracheal stenosis (Only Laryngectomy Tube)

Contraindications

  • Patient under any form of mechanical ventilation.
  • Patients having damaged tracheal or tracheostoma tissue.
  • Allergies to the used material (Silicone, TPE)

Safety

  • Do not reuse: Laryngectomy Tube is intended for single patient use only. Reuse in another patient may cause cross contamination, infection.
  • Do not resterilize – if the Laryngectomy Tube is resterilize, it may cause harm or infection to patient due to Resterilization of device.
  • Do not use the product if the packaging or the product is damaged. This is the only way to ensure the product is germ-free and functional.
  • Do not use lubricating gels if the patient has allergies related to these substances.
  • Only use water-soluble lubricants. Oil-based lubricants may weaken, damage, or destroy the product and should not be used at any time.
  • Patients with bleeding disorders or patients on anticoagulants should not use the device if it causes bleeding that re-occurs.
  • DO NOT use a dirty or contaminated Laryngectomy Button and Laryngectomy Tube. Clean and disinfect the device according to the cleaning and disinfection instructions mentioned in this instruction for use.
  • Do ensure that the patient has been trained in the use of the device. The patient should demonstrate the ability to understand and consistently follow the Instructions for Use without clinician supervision.
  • For more information, please refer to the IFU.

Information for Patients

In the event of malfunction of the device or changes in its performance that may affect safety, or any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the Member State in which the user and/or patient is established.

Troubleshooting information

  • If stoma bleeding occurs, gradually increase device wear time after healing; if bleeding persists, stop using the device and consult your clinician.
  • If the stoma shrinks rapidly, your clinician may recommend using two devices of the same size for easy replacement during cleaning.
  • If the stoma enlarges during use, your clinician may advise using two different-sized devices and considering alternative HME Cassette attachment methods at night.

Material : Silicone or Thermoplastic Elastomer (TPE)

Ref. No. Standard

Ref. No. Fenestrated Specification Inner Diameter (mm) Outer Diameter (mm) Length (mm) Units/Box
ETO Sterile/Non-Sterile
E3110836S E3110836F 8/36 9.5 12.0 36 1 Unit
E3110855S E3110855F 8/55 9.5 12.0 55 1 Unit
E3110936S E3110936F 9/36 10.5 13.5 36 1 Unit
E3110955S E3110955F 9/55 10.5 13.5 55 1 Unit
E3111036S E3111036F 10/36 12.0 15.0 36 1 Unit
E3111055S E3111055F 10/55 12.0 15.0 55 1 Unit
E3111236S E3111236F 12/36 13.5 17.0 36 1 Unit
E3111255S E3111255F 12/55 13.5 17.0 55 1 Unit


Special Instructions

Provide any specific requirements or notes related to your order. Our team will review and accommodate where possible.

EN ISO 13485 Certified

CE Marked Products

Worldwide Export

25+ Years Trusted

Medical Grade Products

You May Also Need

Frequently ordered together

View all products 🡥

Browse by Category

Comprehensive ENT product portfolio engineered for surgical precision.

View all products 🡥

Otology Products
Otology Products

Otology Products

Audiology
Audiology

Audiology

Rhinology Products
Rhinology Products

Rhinology Products

Laryngology Products
Laryngology Products

Laryngology Products

ENT Instruments
ENT Instruments

ENT Instruments

PVA Dressings
PVA Dressings

PVA Dressings

Social Proof

What surgeons say about us

Voices from the operating theatre, ENT specialists across the globe share their experience.

The product quality and consistency are highly reliable. The design reflects a strong understanding of both practitioner needs and patient comfort.

Dr. Emily C

ENT Specialist

The ordering process and product availability have been seamless. We value the consistency in quality and the professionalism in handling bulk requirements.

Michael T

Procurement Manager

The devices integrate well into routine clinical workflows. Ease of use and dependable performance make them a practical choice for daily practice.

Dr. Liam O

Otolaryngologist

From a usability perspective, the products are intuitive and patient-friendly. This significantly improves efficiency during procedures and follow-ups.

Dr. Nathan R

ENT Consultant

The brand demonstrates strong manufacturing standards and reliable supply capabilities, which are essential for maintaining trust in the Australian market.

James W

Healthcare Distributor

The overall build quality and clinical reliability are impressive. The products align well with professional standards and support consistent outcomes in day-to-day practice.

Dr. Olivia B

ENT Surgeon

Support and communication have been excellent. Having a responsive team makes a significant difference in ongoing operations and procurement planning.

Daniel H

Practice Manager

The focus on patient comfort and ease of use is clearly evident. It enhances the overall treatment experience from both clinician and patient perspectives.

Rachel E

Allied Health Professional

Reliable. Compliant. Clinically Designed.

Choose a Trusted ENT Solution

Engineered to meet professional standards and support consistent outcomes in both clinical and home care settings.

EN ISO 13485 Certified

CE Marked Products

Worldwide Shipping

25+ Years Trusted

Medical-Grade Quality

Designed and manufactured under strict clinical standards.

Certified & Compliant

Manufactured in certified facilities aligned with global standards.

Trusted by Professionals

Used by healthcare providers and clinical environments.

Dedicated Support

Guidance and assistance whenever you need it.

Common Questions

Frequently Asked Questions

Have a question not covered here? Our team is ready to help, reach out via email or phone and we'll get back to you within one business day.

Still have questions?

Our clinical and sales teams are happy to assist with product, order, or regulatory queries.

+61 410 737 246

info@eonmeditech.com.au

Who is this product intended for?

This product is designed for use by healthcare professionals and/or individuals, depending on its intended application. Please refer to the product details or consult a medical professional if unsure.

Is this product suitable for home use?

Some products are designed for home use, while others are intended for clinical environments. Check the product specifications to confirm suitability.

Are your products compliant with quality standards?

Yes, all products are manufactured under internationally recognized quality systems and aligned with applicable regulatory requirements.

How do I use this product correctly?

Each product includes usage instructions or guidance materials. For best results, follow the instructions carefully or consult a healthcare professional.

Do you offer bulk or institutional purchasing?

Yes, we support bulk orders for clinics, hospitals, and distributors. Please contact our sales team for more information.

What is the delivery timeline?

Delivery times vary based on location and availability, but we aim to fulfill orders within standard Australian shipping timelines.

What should I do if I need support or face an issue?

If you need assistance, our support team is available to help with product guidance, troubleshooting, or order-related queries.

Stay Updated

Get surgical insights & product updates

Join 2,000+ ENT surgeons and distributors receiving our product newsletters.

info@eonmeditech.com.au

+61 410 737 246

81a Eggleton Street, Blacktown, NSW 2148, AU